Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Development of wall-thinning evaluation procedure for nuclear power plant piping - Part 2: Local wall-thinning estimation methodopen access

Authors
Yun, HunMoon, Seung-JaeOh, Young-Jin
Issue Date
Sep-2020
Publisher
KOREAN NUCLEAR SOC
Keywords
Wall-thinning; Thickness inspection; Wall-thinning estimation; Statistical significance
Citation
NUCLEAR ENGINEERING AND TECHNOLOGY, v.52, no.9, pp.2119 - 2129
Indexed
SCIE
SCOPUS
KCI
Journal Title
NUCLEAR ENGINEERING AND TECHNOLOGY
Volume
52
Number
9
Start Page
2119
End Page
2129
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/8990
DOI
10.1016/j.net.2020.03.001
ISSN
1738-5733
Abstract
Flow-accelerated corrosion (FAC), liquid droplet impingement erosion (LDIE), cavitation and flashing can cause continuous wall-thinning in nuclear secondary pipes. In order to prevent pipe rupture events resulting from the wall-thinning, most NPPs (nuclear power plants) implement their management programs, which include periodic thickness inspection using UT (ultrasonic test). Meanwhile, it is well known in field experiences that the thickness measurement errors (or deviations) are often comparable with the amount of thickness reduction. Because of these errors, it is difficult to estimate wall-thinning exactly whether the significant thinning has occurred in the inspected components or not. In the previous study, the authors presented an approximate estimation procedure as the first step for thickness measurement deviations at each inspected component and the statistical & quantitative characteristics of the measurement deviations using plant experience data. In this study, statistical significance was quantified for the current methods used for wall-thinning determination. Also, the authors proposed new estimation procedures for determining local wall-thinning to overcome the weakness of the current methods, in which the proposed procedure is based on analysis of variance (ANOVA) method using sub-grouping of measured thinning values at all measurement grids. The new procedures were also quantified for their statistical significance. As the results, it is confirmed that the new methods have better estimation confidence than the methods having used until now. (C) 2020 Korean Nuclear Society, Published by Elsevier Korea LLC.
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Seung Jae photo

Moon, Seung Jae
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE