냉복도 밀폐시스템의 적용에 의한 데이터센터 서버실의 냉방에너지 절감 효과 분석Analysis of Cooling Energy Saving by Cold Aisle Containment System in Internet Data Center Server Room

Other Titles
Analysis of Cooling Energy Saving by Cold Aisle Containment System in Internet Data Center Server Room
Authors
장현재정용호서장후
Issue Date
2012
Publisher
한국건축친환경설비학회
Keywords
CRAC; Data center; Energy cost; Cold aisle containment system; Re-circulation air; Cold aisle; 항온항습기; 데이터 센터; 에너지 비용; 밀폐형 쿨링시스템; 재순환공기; 냉복도
Citation
한국건축친환경설비학회 논문집, v.6, no.3, pp.181 - 190
Journal Title
한국건축친환경설비학회 논문집
Volume
6
Number
3
Start Page
181
End Page
190
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/19353
ISSN
1976-6483
Abstract
In order to keep the server room temperature condition, energy consumption has been rapidly increased as the increasing internal heat gain of server room in data center. And the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. There are many wastes of cooling energy which is caused by the structural problems in data center server room. For example, a leakage by the electric cable hole, mixing or recirculation of hot air from the hot aisle to the cold aisle, short circulation of the CRAC(Computer Room Air Conditioning), and others. So there are many strategies to reduce the waste of cooling energy in data center. In this study, cold aisle containment system was proposed among the various strategies to reduce the waste energy by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, test bed which is same with exist server room was set up in IDC(Internet Data Center) building. And comparative experiments, conventional open type cooling system and cold aisle containment sysetm, were carried out in actual conditions. As the result, the range of inlet temperature of server system was 20~25℃ in exist cooling system and the range of inlet temperature dropped below 20℃ by cold aisle containment system. After all, was possible by the cold aisle containment system and cold aisle containment system was proved to be the solution for energy saving cooling system.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Major in Architecture Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Hyun jae photo

Chang, Hyun jae
Science & Technology (Architectural Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE