Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Encoder Calibration Method for High Precision Servo Systems With a Sinusoidal Encoder

Authors
Lee, YoungwooKim, Sang HyunLee, Seung-HiChung, Chung Choo
Issue Date
1-Jan-2022
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Calibration; Signal resolution; Acceleration; Servomotors; Velocity measurement; Real-time systems; Indexes; Fictitious cosine function; phase distribution; phase shift calibration; sinusoidal encoder
Citation
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, v.69, no.1, pp.752 - 762
Journal Title
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
Volume
69
Number
1
Start Page
752
End Page
762
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/20968
DOI
10.1109/TIE.2021.3051599
ISSN
0278-0046
Abstract
The sinusoidal encoder is used as an absolute position (velocity) transducer to implement the position (velocity) of actuators in many industrial applications. However, the performance of the position (velocity) can be degraded due to nonideal factors such as differential amplitudes of the encoder signals, offset, and phase shift. To analyze this problem, we formulate the relationship between the coefficients of ideal signals and the nonideal signals characteristic, which is an ellipse formed by plotting the encoder signals versus each other. In this article, we propose a nonideal signal calibration for the imperfect components of existing sinusoidal signals to improve position (velocity) regulation performance. The fictitious cosine function is used to detect the phase shift between the sine and cosine signals, and it can be designed by using the frequency of sinusoidal signals. The proposed method is validated by simulation and experimental implementation, showing noticeable improvement in estimating nonideal signal components, Lissajous error curve, phase distribution, and the position (velocity) error signal. Experimental results show that the proposed method is able to obtain the components of the nonideal signals and the accurate position (velocity) with a small error in real time, while other calibration methods are difficult to apply to fast motion.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical and System Design Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Seung Hi photo

Lee, Seung Hi
Engineering (Mechanical & System Design Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE