Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

단순 방사선에서의 한국인의 정상 근위 대퇴부의 해부학적 측정 : 항회전 근위 대퇴 골수정을 이용한 수술 시 문제점Anatomical Measurement of Normal Korean Proximal Femur Using Plain Radiography : A Problem when using Proximal Femoral Nail Anti-rotation

Other Titles
Anatomical Measurement of Normal Korean Proximal Femur Using Plain Radiography : A Problem when using Proximal Femoral Nail Anti-rotation
Authors
박종석김우종소재완장병웅김태헌서유성
Issue Date
2011
Publisher
대한고관절학회
Keywords
대퇴부; 항회전 대퇴 골수정; 단순 방사선; 측정; Femur; Proximal femoral nail anti-rotation; Plain radiography; Measure
Citation
Hip and Pelvis, v.23, no.4, pp.303 - 309
Journal Title
Hip and Pelvis
Volume
23
Number
4
Start Page
303
End Page
309
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/16961
ISSN
2287-3260
Abstract
Purpose: We propose to improve the use of Proximal Femoral Nail Anti-rotation in Korea by reporting anatomical measurements of the normal Korean proximal femur. Materials and Methods: A total of 230 patients were enrolled who had all experienced a femoral intertrochanteric fracture and undergone the Proximal Femoral Nail Anti-rotation surgical procedure between February 2007 and April 2011. We measured the neck-shaft angle and endosteal width at the isthmus of a normal femur, and the distance between the greater trochanter and the nail tip of the Proximal Femoral Nail Anti-rotation in post-operative plain radiography. We analyzed the average and standard deviations of the measurements. We also investigated correlations with the patient gender. Results: The average neck-shaft angle and endosteal width at the isthmus were 129.7。(111.0~138.3。) and 14.5 mm (9.7~23.1 mm), respectively. The average protruded nail length was 4.9 mm (1.0~15.0 mm). The femur neck-shaft angle had a correlation ratio with gender (p=0.000). However, the endosteal width at the isthmus level and the protruded nail length had no correlation ratio with gender (p=0.108, 0.573, respectively). Conclusion: Until now, in intertrochanteric fracture operations using Proximal Femoral Nail Anti-rotation, the selection of devices has been extremely limited. Through this study we present the average Korean anatomical neckshaft angle, endosteal width of the femur, and protruding length of the nail tip. We expect that these numerical values can be used in the production of new devices with shorter proximal nails, which would be more appropriates for Koreans.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE