Calibration of in-plane center alignment errors in the installation of a circular slide with machine- vision sensor and a reflective marker
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, Hyungjin | - |
dc.contributor.author | Yu, Jiwon | - |
dc.contributor.author | Lee, Donghun | - |
dc.date.available | 2020-11-23T03:40:15Z | - |
dc.date.created | 2020-11-19 | - |
dc.date.issued | 2020-10 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/40033 | - |
dc.description.abstract | This paper describes a method for calibrating in-plane center alignment error (IPCA) that occurs when installing the circular motion slide (CMS). In this study, by combini ng the moving carriage of the CMS and the planar PKM (parallel kinematic mechanism) with the machine tool, the small workspace of the PKM is expanded, and the workpiece is placed on the table with the CMS installed is processed through the machine tool. However, to rigidly mount the CMS on the table, the preload between the guide and the support bearings must be adjusted with the eccentric bearing, and in this process, the IPCA occurs. After installing a reflective marker on the PKM, the PKM is slowly rotated along with the ring guide in the way of stop-and-go without the PKM’s own motion. Then, using a machine vision camera installed at the top of the CMS, the IPCA, which is the difference between the actual center position and the nominal center position of the CMS with respect to the camera, can be successfully calibrated through the circular fitting process. Consequently, it was confirmed that the IPCA of 0.37 mm can be successfully identified with the proposed method. © 2020 by the authors. Licensee MDPI, Basel, Switzerland. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.language.iso | en | - |
dc.publisher | MDPI AG | - |
dc.relation.isPartOf | Sensors (Switzerland) | - |
dc.title | Calibration of in-plane center alignment errors in the installation of a circular slide with machine- vision sensor and a reflective marker | - |
dc.type | Article | - |
dc.identifier.doi | 10.3390/s20205916 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | Sensors (Switzerland), v.20, no.20, pp.1 - 15 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000585581200001 | - |
dc.identifier.scopusid | 2-s2.0-85094154089 | - |
dc.citation.endPage | 15 | - |
dc.citation.number | 20 | - |
dc.citation.startPage | 1 | - |
dc.citation.title | Sensors (Switzerland) | - |
dc.citation.volume | 20 | - |
dc.contributor.affiliatedAuthor | Lee, Donghun | - |
dc.type.docType | Letter | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Circle fitting | - |
dc.subject.keywordAuthor | Circular slide | - |
dc.subject.keywordAuthor | In-plane center-alignment error calibration | - |
dc.subject.keywordAuthor | Machine vision | - |
dc.subject.keywordAuthor | Parallel mechanism | - |
dc.subject.keywordPlus | Alignment | - |
dc.subject.keywordPlus | Bearings (machine parts) | - |
dc.subject.keywordPlus | Cameras | - |
dc.subject.keywordPlus | Turing machines | - |
dc.subject.keywordPlus | Alignment error | - |
dc.subject.keywordPlus | Circular motion | - |
dc.subject.keywordPlus | Machine vision cameras | - |
dc.subject.keywordPlus | Parallel kinematic mechanisms | - |
dc.subject.keywordPlus | Pre loads | - |
dc.subject.keywordPlus | Stop-and-go | - |
dc.subject.keywordPlus | Support bearings | - |
dc.subject.keywordPlus | Workpiece | - |
dc.subject.keywordPlus | Computer vision | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.