Abstract
This study represent an experimental study of PCM floor radiant heating system. The results obtained from the study are summarized as follows; 1) PCM floor radiant heating system is an insertion of a 10 mm thick PCM into the existing standard floor structure, which has the advantage of good construct ability due to no additional process. 2) It was confirmed that the PCM thread remains higher than the normal room. In particular, it was found that the temperature of hot water pipes under the pipes was maintained at 36℃ or higher after four hours after the boiler was stopped. Therefore, we have seen that the room temperature of the PCM floor radiant heating system is longer than the general floor heating system, PCM Floor Radiant Heating is considered to improve the comfort of indoor residents.
This study represent an experimental study of PCM floor radiant heating system. The results obtained from the study are summarized as follows; 1) PCM floor radiant heating system is an insertion of a 10 mm thick PCM into the existing standard floor structure, which has the advantage of good construct ability due to no additional process. 2) It was confirmed that the PCM thread remains higher than the normal room. In particular, it was found that the temperature of hot water pipes under the pipes was maintained at 36℃ or higher after four hours after the boiler was stopped. Therefore, we have seen that the room temperature of the PCM floor radiant heating system is longer than the general floor heating system, PCM Floor Radiant Heating is considered to improve the comfort of indoor residents.
Files in This Item
Appears in
Collections
College of Engineering > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jin Chul photo

Park, Jin Chul
공과대학 (건축공학)
Read more

Altmetrics

Total Views & Downloads

BROWSE