Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A short-cut graphical method for sizing of recycle valves in anti-Surge system considering time delay

Authors
Oh, YutaekLee, Chul-JinLim, Youngsub
Issue Date
Oct-2017
Publisher
ELSEVIER SCI LTD
Keywords
Process design; Compressor; Sizing method; Anti-surge valves; Dynamic simulation
Citation
JOURNAL OF PROCESS CONTROL, v.58, pp 23 - 32
Pages
10
Journal Title
JOURNAL OF PROCESS CONTROL
Volume
58
Start Page
23
End Page
32
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/3903
DOI
10.1016/j.jprocont.2017.08.009
ISSN
0959-1524
1873-2771
Abstract
A surge in a centrifugal compressor can cause critical damage to the compressor, resulting in large repair costs, so one of the most important considerations in the design of compressor systems is to prevent a surge. However, conventional methods to size recycle valves in anti-surge systems are limited in that the valve characteristics and time delay cannot be quantitatively considered. This paper suggested a shortcut graphical method to easily size the recycle valves in an anti-surge system by considering the valve characteristics, including the dead time, actuation time, and opening types. Dynamic simulations were carried out to verify the resulting size of the valves, and the results of the simulation showed that a surge could be avoided effectively and economically. (C) 2017 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Chemical Engineering and Material Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Chul-Jin photo

Lee, Chul-Jin
대학원 (지능형에너지산업융합학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE