Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reducing the energy cost of running using a lightweight, low-profile elastic exosuit

Authors
Yang, J.Park, J.Kim, J.Park, S.Lee, G.
Issue Date
30-Aug-2021
Publisher
BioMed Central Ltd
Keywords
Assistive device; Metabolic cost; Passive exosuit; Running assistance; Spatiotemporal parameters
Citation
Journal of NeuroEngineering and Rehabilitation, v.18, no.1
Journal Title
Journal of NeuroEngineering and Rehabilitation
Volume
18
Number
1
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/49358
DOI
10.1186/s12984-021-00928-x
ISSN
1743-0003
1743-0003
Abstract
Background: Human beings can enhance their distance running performance with the help of assistive devices. Although several such devices are available, they are heavy and bulky, which limits their use in everyday activities. In this study, we developed a lightweight running assistive device with a low-profile design. The device applies a flexion moment to the hip according to the hip extension within a specific range of motion to assist running. Methods: A passive exosuit was fabricated using textile materials and elastic bands. The deformation of the suit was measured and compensated for in the design. The fabricated suit was tested on eight participants (age: 24.4 ± 3.8 y; height: 1.72 ± 0.05 m; weight: 74.5 ± 6.1 kg) who were instructed to run on a treadmill at a speed of 2.5 m/s. Through indirect calorimetry, the metabolic rate was measured for the no-suit condition and three band conditions. Variations in the spatiotemporal parameters were measured using a motion capture system and force-sensing resistors (FSRs). Results: When using the fabricated device, seven out of the eight participants exhibited a reduced metabolic rate in at least one of the three band conditions. An average reduction of − 4.7 ± 1.4% (mean ± standard error of the mean (s.e.m.), two-sided paired t-test, p = 0.017) was achieved when using the best-fitting bands compared to the average of the two no-suit conditions. No statistically significant changes were observed in the spatiotemporal parameters, except for the stance duration in the medium assistance force condition. Conclusions: The proposed passive exosuit, which has a low weight of 609 g and small extrusion of 2.5 cm from the body in standing posture, can reduce the metabolic rate during running. The proposed device can potentially be used every day owing to its low-profile design and low weight, thereby overcoming the limitations of existing portable devices targeting the hip joints. © 2021, The Author(s).
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Gi Uk photo

Lee, Gi Uk
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE