Analysis of the Efficacy of Universal Screening of Coronavirus Disease with Antigen-Detecting Rapid Diagnostic Tests at Point-or-Care Settings and Sharing the Experience of Admission Protocol—A Pilot Studyopen access

Authors
Park, J.Y.Lee, J.H.Cha, B.K.Kim, B.-S.Lee, H.-J.Kim, G.H.Kang, K.-T.Lee, Y.-S.Ahn, S.K.Kim, S.H.
Issue Date
Feb-2022
Publisher
MDPI
Keywords
COVID-19; Cross infection; Infection control; SARS-CoV-2
Citation
Journal of Personalized Medicine, v.12, no.2
Journal Title
Journal of Personalized Medicine
Volume
12
Number
2
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/61659
DOI
10.3390/jpm12020319
ISSN
2075-4426
2075-4426
Abstract
Aims: To introduce the admission protocol of a COVID-19 specialized hospital outlined by the government, including the assessment of reverse transcription polymerase chain reaction (RT-PCR), low dose chest computed tomography (CT) and antigen-detecting rapid diagnostic test (Ag-RDT) for patient screening. Materials and Methods: This was a retrospective cohort study of 646 patients who were admitted between December 2020, and February 2021, during the third wave of COVID-19 in Korea. Ag-RDT and RT-PCR were routinely performed on all patients who required admission, and low-dose chest CT was performed on high-risk patients with associated symptoms. Any patients with high-risk COVID-19 infection according to the Ag-RDT test were quarantined alone in a negative pressured room, and those with low-risk COVID-19 infection remained in the preemptive quarantine room with or without negative pressure. The diagnostic values of the Ag-RDT test and associated cycle threshold (Ct) values of the RT-PCR test were subsequently evaluated. Results: In terms of the diagnostic value, the Ag-RDT for COVID-19 had a sensitivity of 68.3%, specificity of 99.5%, positive predictive value (PPV) of 90.3%, and negative predictive value (NPV) of 97.9%. For the 355 symptomatic patients with low-dose chest CT, the diagnostic values of combined evaluations had a sensitivity of 90.2%, specificity of 99.0%, PPV of 86.1%, and NPV of 99.3%. The cut-off Ct value for positive Ag-RDT was ≤25.67 for the N gene (sensitivity: 89.3%, specificity: 100%), which was regarded as a high viable virus in cell culture. There were no patients or medical staff who had COVID-19 in the hospital. Conclusion: Appropriate patient care was possible by definitive triage of the area, according to the symptoms and using diagnostic tests. Screening protocols, including the Ag-RDT test and low-dose chest CT, could be helpful in emergency point-of-care settings. © 2022 by the authors. Licensee MDPI, Basel, Switzerland.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Han Jun photo

Lee, Han Jun
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE