Detailed Information

Cited 8 time in webofscience Cited 8 time in scopus
Metadata Downloads

Drug response of captured BT20 cells and evaluation of circulating tumor cells on a silicon nanowire platform

Authors
Kim, Dong-JooLee, Won-YongPark, No-WonKim, Gil-SungLee, Kyung-MinKim, JongjinChoi, Mun-KiLee, Gee HeeHan, WonshikLee, Sang-Kwon
Issue Date
May-2015
Publisher
ELSEVIER ADVANCED TECHNOLOGY
Keywords
Cell capture; Circulating tumor cells (CTCs); Streptavidin functionalization; Silicon nanowires; Drug response; Breast cancer patient blood
Citation
BIOSENSORS & BIOELECTRONICS, v.67, pp 370 - 378
Pages
9
Journal Title
BIOSENSORS & BIOELECTRONICS
Volume
67
Start Page
370
End Page
378
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/9562
DOI
10.1016/j.bios.2014.08.057
ISSN
0956-5663
1873-4235
Abstract
Research on specific drug responses of circulating tumor cells (CTCs) provides very important information for treatment of cancer patients at a patient-specific level. For this reason, platforms for high capture efficiency of CTCs are essential for clinical evaluation of patient-specific drug responses of CTCs. Recently, nanostructure based platforms have been developed with a high capture efficiency of more than 93% due to high-affinity binding and the 3D nanotopographic features of the nanostructure substrate. In this study, the breast carcinoma cell-line (BT20) cells with an ultra-low abundance range were captured by streptavidin (STR)-functionalized silicon nanowire (SiNW) platforms for evaluation of capture efficiency. A capture efficiency of more than 90% was achieved. Specific drug responses of BT20 cells captured on STR-SiNW platforms were analyzed using tamoxifen or docetaxel as a function of incubation time and dose, and compared with a 96-well plate platform. The drug responses of CTCs on STR-SiNW platforms were more sensitive than a 96-well plate platform. In addition, CTCs were successfully captured and evaluated their size distribution from the blood of breast cancer patients using fluorescence imaging. In conclusion, we suggest that the SiNW platform is adaptable for clinical use in evaluation of CTCs and drug response tests. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sang Kwon photo

Lee, Sang Kwon
자연과학대학 (물리학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE