Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The active von Frey filament test: A new technique to evaluate hand tactile sensation in continuous variable units

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Jong Woo-
dc.contributor.authorLee, Hyun-Joo-
dc.contributor.authorLee, Jong-Gyeong-
dc.contributor.authorOh, Dong-Hoon-
dc.contributor.authorKim, Junghoon-
dc.contributor.authorLee, Ji-Woon-
dc.contributor.authorJeon, In-Ho-
dc.contributor.authorChoi, Youngjin-
dc.date.accessioned2022-07-18T01:20:18Z-
dc.date.available2022-07-18T01:20:18Z-
dc.date.issued2022-02-
dc.identifier.issn2468-1229-
dc.identifier.issn2468-1210-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/107984-
dc.description.abstractThe von Frey filament test (vF) is a mainstay of clinical examination. However, its results can be affected by touch speed and other potentially confounding factors. Moreover, the differences between two adjacent filament levels are too large to detect subtle changes. Active vF (AvF) was developed to induce in-depth sensory change. The present study hypothesized that AvF produces different patterns of fingertip sensation; consequently, it could be used as a new assessment tool for neural impairment. The aim of the study was to provide preliminary normative comparative vF and AvF data. This study prospectively examined 32 healthy participants, using AvF and vF. The index and the fifth finger volar pad were examined using AvF and vF, without visual stimulation. The correlation between AvF and vF measurements was evaluated. In addition, differences according to innervation zone, right versus left hand, and gender, and the correlation between AvF values and subjects' age were analyzed. Mean AvF value was significantly higher and had greater variance than vF (111.3 +/- 46.9 vs. 24.1 +/- 9.8; P < 0.01). The Spearman correlation coefficient between AvF and vF was 0.341. Values were similar in the index and fifth fingers and right and left hands. However, values were significantly different between women and men. The correlation between age and AvF values was 0.259. AvF provided more precise values, with continuous units for tactile sensation, excluding tester-dependent factors. Furthermore, AvF and vF values may not be correlated. (C) 2021 SFCM. Published by Elsevier Masson SAS. All rights reserved.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleThe active von Frey filament test: A new technique to evaluate hand tactile sensation in continuous variable units-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.hansur.2021.11.003-
dc.identifier.scopusid2-s2.0-85120860305-
dc.identifier.wosid000749607200014-
dc.identifier.bibliographicCitationHand Surgery and Rehabilitation, v.41, no.1, pp 85 - 89-
dc.citation.titleHand Surgery and Rehabilitation-
dc.citation.volume41-
dc.citation.number1-
dc.citation.startPage85-
dc.citation.endPage89-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlus2-POINT DISCRIMINATION-
dc.subject.keywordPlusTHRESHOLDS-
dc.subject.keywordPlusPRESSURE-
dc.subject.keywordAuthorD'Arsonval movement-
dc.subject.keywordAuthorSensory test-
dc.subject.keywordAuthorObjective-
dc.subject.keywordAuthorSemi-automated-
dc.subject.keywordAuthorvon Frey filament test-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S2468122921006265?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF ROBOT ENGINEERING > 1. Journal Articles