Comparison of AC and DC Partial Discharge by Monitoring of Vacuum Degree in a Distribution Class Vacuum Interrupteropen access

Authors
Bang, SeungminLee, Hyun-WooLee, Bang-Wook
Issue Date
Mar-2022
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
AC; DC; distribution class; dielectric strength; partial discharge; PRPD; PSA; monitoring; maintenance criteria; vacuum interrupter
Citation
IEEE Access, v.10, pp 36254 - 36267
Pages
14
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
10
Start Page
36254
End Page
36267
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/111285
DOI
10.1109/ACCESS.2022.3163448
ISSN
2169-3536
Abstract
The vacuum degree of Vacuum Interrupter (VI) will deteriorate because of gases emitted by arc heat, and leakage through the joints. It is important to select an appropriate maintenance criteria for a VI by monitoring the vacuum degree. However, monitoring of a VI installed inside a solid insulation apparatus in a transmission system is impossible. Only studies on the insulation deterioration because of the decrease of the vacuum degree have been conducted, and important factors such as the maintenance criteria have not been investigated. Moreover, most studies have only been performed using AC voltage, not DC voltage. Therefore, in this paper, AC and DC partial discharge were compared by monitoring of the vacuum degree in a distribution class VI to propose maintenance criteria according to voltage type. Through this, for efficient maintenance, maintenance criteria of VI for each voltage type are presented. The vacuum degree at which the dielectric strength rapidly decreases was confirmed according to voltage type. The coupling capacitor was installed directly on the floating shield of VI. Moreover, to measure the pattern and apparent charge of partial discharge according to the vacuum degree, phase resolved partial discharge (PRPD) for AC partial discharge and pulse sequence analysis (PSA) for DC partial discharge were adopted. It is found that maintenance should be performed when the vacuum degree is in the range of 10(-3) similar to 10(-2) torr regardless of the voltage type. Moreover, the usefulness of the technology is higher at AC voltage than at DC voltage.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Bang Wook photo

Lee, Bang Wook
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE