Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Estimation of gamma-rays, and fast and the thermal neutrons attenuation characteristics for bismuth tellurite and bismuth boro-tellurite glass systems

Authors
Lakshminarayana, GandhamKebaili, ImenDong,MenggeAl-Buriahi, Mohammed SultanDahshan, A.Kityk,Iwan V.Lee, Dong-EunYoon, JonghunPark, Taejoon
Issue Date
May-2020
Publisher
SPRINGER
Citation
JOURNAL OF MATERIALS SCIENCE, v.55, no.14, pp.5750 - 5771
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF MATERIALS SCIENCE
Volume
55
Number
14
Start Page
5750
End Page
5771
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/1113
DOI
10.1007/s10853-020-04446-4
ISSN
0022-2461
Abstract
Gamma-rays and fast and thermal neutron attenuation features of (Bi2O3)(x)-(TeO2)((100-x)) (where x = 5, 8, 10, 12, and 15 mol%) and [(TeO2)(0.7)-(B2O3)(0.3)]((1-x))-(Bi2O3)(x) (where x = 0.05, 0.10, 0,15, 0.20, 0.25, and 0.3 mol%) glass systems have been explored and compared. For all samples, mass attenuation coefficients (mu/rho) are estimated within 0.015-15 MeV photon energy range by MCNP5 simulation code and correlated with WinXCom results, which showed a satisfactory agreement between computed mu/rho values by these both methods. Additionally, effective atomic number (Z(eff)), effective electron density (N-eff), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), total atomic cross-section (sigma(a)), and total electronic cross-section (sigma(e)) are calculated by utilizing mu/rho values. The mu/rho, Z(eff), and N-eff are energy dependent and have higher values at the lowest energy and smaller values at higher energies. Moreover, using the G-P fitting method as a function of penetration depth (up to 40 mfp) and incident photon energy (0.015-15 MeV range), exposure buildup factors (EBFs) and energy absorption buildup factors (EABFs) are evaluated. Both 85TeO(2)-15Bi(2)O(3) (mol%) and 49TeO(2)-21B(2)O(3)-30Bi(2)O(3) (mol%) samples, by possessing higher values of Z(eff), exhibit minimum EBF and EABF values. Highest mu/rho, Z(eff) values and lowest HVL, TVL, MFP values of 49TeO(2)-21B(2)O(3)-30Bi(2)O(3) (mol%) sample indicated its better gamma-ray absorption capability among all selected glasses. Further, macroscopic effective removal cross-section for fast neutrons (sigma(R)), coherent scattering cross-section (sigma(cs)), incoherent scattering cross-section (sigma(ics)), absorption cross-section (sigma(A)), and total cross-section (sigma(T)) values for thermal neutron attenuation have been computed. Among all samples, 49TeO(2)-21B(2)O(3)-30Bi(2)O(3) (mol%) glass possesses a better sigma(R) value for fast neutron attenuation, while the largest 'sigma(T)' value of 66.5TeO(2)-28.5B(2)O(3)-5Bi(2)O(3) (mol%) sample suggests its good thermal neutron absorption efficiency.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF ROBOT ENGINEERING > 1. Journal Articles
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF MECHANICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Tae joon photo

Park, Tae joon
ERICA 공학대학 (DEPARTMENT OF ROBOT ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE