Measurement of the activation volume in magnetic random access memory
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Moosung | - |
dc.contributor.author | Carpenter, Robert | - |
dc.contributor.author | Gama, Monteiro M. | - |
dc.contributor.author | Van Beek, Simon | - |
dc.contributor.author | Kim, Jongryoul | - |
dc.contributor.author | Couet, Sebastien | - |
dc.date.accessioned | 2023-07-05T05:33:01Z | - |
dc.date.available | 2023-07-05T05:33:01Z | - |
dc.date.issued | 2023-02 | - |
dc.identifier.issn | 0021-8979 | - |
dc.identifier.issn | 1089-7550 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/112946 | - |
dc.description.abstract | Measuring thermal stability in magnetic random access memory devices is non-trivial. Recently, there has been much discussion on the appropriate model to use: single domain or domain wall nucleation. Of particular challenge is assessing the maximum size at which the single domain model can be assumed. Typically, this is estimated to be in the range of 20-30 nm based on a value of the exchange stiffness (A e x) that is assumed, estimated using indirect measurements or derived from significantly thicker films. In this work, it is proposed that this maximum size can be measured directly via the activation volume(V a c t) or the activation diameter(D a c t), which originates from the concept of magnetic viscosity. This is conducted by measuring, using the time dependence of magnetization at different applied fields, D a c t in perpendicular magnetic tunnel junction pillars of varying effective anisotropy constant (K e f f) and diameter. It is shown that the trend in D a c t follows 1 / K e f f dependence, in good agreement with the analytic model for the critical diameter of coherent switching. Critically, it is also found that the smallest size for which a single domain, with coherent reversal, occurs is 20 nm. Thus, in devices with technologically relevant values of K e f f, the macrospin model may only be used in 20 nm, or smaller, devices. © 2023 Author(s). | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | American Institute of Physics Inc. | - |
dc.title | Measurement of the activation volume in magnetic random access memory | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1063/5.0135948 | - |
dc.identifier.scopusid | 2-s2.0-85148770563 | - |
dc.identifier.wosid | 000958356700004 | - |
dc.identifier.bibliographicCitation | Journal of Applied Physics, v.133, no.7, pp 1 - 8 | - |
dc.citation.title | Journal of Applied Physics | - |
dc.citation.volume | 133 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 8 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.identifier.url | https://pubs.aip.org/aip/jap/article/133/7/073901/2876682/Measurement-of-the-activation-volume-in-magnetic | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
55 Hanyangdeahak-ro, Sangnok-gu, Ansan, Gyeonggi-do, 15588, Korea+82-31-400-4269 sweetbrain@hanyang.ac.kr
COPYRIGHT © 2021 HANYANG UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.