Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fault Current Limiter and Mechanical DC CB based Protection against Valve-side SPG Faults in HB-MMC Bipolar System

Full metadata record
DC Field Value Language
dc.contributor.authorUsman, Muhammad-
dc.contributor.authorKwak, Yu-Jin-
dc.contributor.authorLee, Bang-Wook-
dc.date.accessioned2025-05-16T08:01:19Z-
dc.date.available2025-05-16T08:01:19Z-
dc.date.issued2025-04-
dc.identifier.issn2169-3536-
dc.identifier.issn2169-3536-
dc.identifier.urihttps://scholarworks.bwise.kr/erica/handle/2021.sw.erica/125283-
dc.description.abstractValve-side single-phase-to-ground (SPG) faults are atypical yet critical for the operation of half-bridge (HB) Modular Multilevel converter (MMC) bipolar or asymmetrical monopolar systems. For the impacted converter station, these faults may result in non-zero crossing currents on the connected AC grid and cause significant overvoltage on upper arm submodule (SM) capacitors. This article presents an SPG valve-side fault mitigation strategy using a power electronic (PE) fault current limiter (FCL) installed at the grounded terminal of the MMC converter, along with a mechanical DC breaker on the DC transmission line. The FCL transfers converter ground current to a resistive branch during the SPG fault, resulting in zero crossing currents on the AC side of the grid, thus ensuring fault current clearance by grid-side AC circuit breakers. Moreover, the proposed topology limits the fault current magnitude, reducing the impact of SPG valve-side faults on the AC grid. The discontinuous DC line current is cleared by a fast mechanical DC circuit breaker, halting the charging of the upper arm SM capacitor and limiting the overvoltage stress on converter insulation. In addition, the severity of upper arm SM overvoltage in case of SPG fault in long distance HB-MMC bipolar links has been assessed, and the prospect of a passive oscillation DC circuit breaker to curb such overvoltage has been demonstrated. The effectiveness of the protection topology has been verified through PSCAD/EMTDC software and compared with previously proposed SPG fault clearance methods. © 2013 IEEE.-
dc.format.extent15-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleFault Current Limiter and Mechanical DC CB based Protection against Valve-side SPG Faults in HB-MMC Bipolar System-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/ACCESS.2025.3556936-
dc.identifier.scopusid2-s2.0-105002128883-
dc.identifier.wosid001463496200016-
dc.identifier.bibliographicCitationIEEE Access, v.13, pp 59826 - 59840-
dc.citation.titleIEEE Access-
dc.citation.volume13-
dc.citation.startPage59826-
dc.citation.endPage59840-
dc.type.docTypeArticle in press-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTelecommunications-
dc.relation.journalWebOfScienceCategoryComputer Science, Information Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryTelecommunications-
dc.subject.keywordPlusMODULAR MULTILEVEL CONVERTERS-
dc.subject.keywordPlusTO-GROUND FAULTS-
dc.subject.keywordPlusHVDC-
dc.subject.keywordAuthorDC circuit breaker-
dc.subject.keywordAuthorMMC-HVDC bipolar links-
dc.subject.keywordAuthorPassive oscillation DC circuit breaker-
dc.subject.keywordAuthorPSCAD/EMTDC program-
dc.subject.keywordAuthorsingle-phase valve-side MMC fault-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/10946980-
Files in This Item
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher