Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparative study of superconducting fault current limiter both for LCC-HVDC and VSC-HVDC systems

Authors
Lee, Jong-GeonKhan, Umer AmirLim, Sung-WooShin, Woo-juSeo, In-JinLee, Bang-Wook
Issue Date
Nov-2015
Publisher
Elsevier BV
Keywords
DC fault current limitation; HVDC fault current analysis; HVDC grid protection; LCC-HVDC; Resistive superconducting fault current limiter (SFCL); VSC-HVDC
Citation
Physica C: Superconductivity and its Applications, v.518, pp.149 - 153
Indexed
SCIE
SCOPUS
Journal Title
Physica C: Superconductivity and its Applications
Volume
518
Start Page
149
End Page
153
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/16517
DOI
10.1016/j.physc.2015.02.043
ISSN
0921-4534
Abstract
High Voltage Direct Current (HVDC) system has been evaluated as the optimum solution for the renewable energy transmission and long-distance power grid connections. In spite of the various advantages of HVDC system, it still has been regarded as an unreliable system compared to AC system due to its vulnerable characteristics on the power system fault. Furthermore, unlike AC system, optimum protection and switching device has not been fully developed yet. Therefore, in order to enhance the reliability of the HVDC systems mitigation of power system fault and reliable fault current limiting and switching devices should be developed. In this paper, in order to mitigate HVDC fault, both for Line Commutated Converter HVDC (LCC-HVDC) and Voltage Source Converter HVDC (VSC-HVDC) system, an application of resistive superconducting fault current limiter which has been known as optimum solution to cope with the power system fault was considered. Firstly, simulation models for two types of LCC-HVDC and VSC-HVDC system which has point to point connection model were developed. From the designed model, fault current characteristics of faulty condition were analyzed. Second, application of SFCL on each types of HVDC system and comparative study of modified fault current characteristics were analyzed. Consequently, it was deduced that an application of AC-SFCL on LCC-HVDC system with point to point connection was desirable solution to mitigate the fault current stresses and to prevent commutation failure in HVDC electric power system interconnected with AC grid. (C) 2015 Elsevier B.V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Bang Wook photo

Lee, Bang Wook
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE