Assessment on the influence of resistive superconducting fault current limiter in VSC-HVDC system

Authors
Lee, Jong-GeonKhan, Umer AmirHwang, Jae-SangSeong, Jae-KyuShin, Woo-JuPark, Byung-BaeLee, Bang-Wook
Issue Date
Sep-2014
Publisher
Elsevier BV
Keywords
HVDC fault analysis; HVDC power grid design; Superconducting; Fault current limiters; VSC HVDC
Citation
Physica C: Superconductivity and its Applications, v.504, pp 163 - 166
Pages
4
Indexed
SCI
SCIE
SCOPUS
Journal Title
Physica C: Superconductivity and its Applications
Volume
504
Start Page
163
End Page
166
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/21940
DOI
10.1016/j.physc.2014.03.019
ISSN
0921-4534
1873-2143
Abstract
Due to fewer risk of commutation failures, harmonic occurrences and reactive power consumptions, Voltage Source Converter (VSC) based HVDC system is known as the optimum solution of HVDC power system for the future power grid. However, the absence of suitable fault protection devices for HVDC system hinders the efficient VSC-HVDC power grid design. In order to enhance the reliability of the VSC-HVDC power grid against the fault current problems, the application of resistive Superconducting Fault Current Limiters (SFCLs) could be considered. Also, SFCLs could be applied to the VSC-HVDC system with integrated AC Power Systems in order to enhance the transient response and the robustness of the system. In this paper, in order to evaluate the role of SFCLs in VSC-HVDC systems and to determine the suitable position of SFCLs in VSC-HVDC power systems integrated with AC power System, a simulation model based on Korea Jeju-Haenam HVDC power system was designed in Matlab Simulink/SimPowerSystems. This designed model was composed of VSC-HVDC system connected with an AC microgrid. Utilizing the designed VSC-HVDC systems, the feasible locations of resistive SFCLs were evaluated when DC line-to-line, DC line-to-ground and three phase AC faults were occurred. Consequently, it was found that the simulation model was effective to evaluate the positive effects of resistive SFCLs for the effective suppression of fault currents in VSC-HVDC systems as well as in integrated AC Systems. Finally, the optimum locations of SFCLs in VSC-HVDC transmission systems were suggested based on the simulation results. (C) 2014 Elsevier B.V. All rights reserved.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Bang Wook photo

Lee, Bang Wook
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE