Development and Structural Assessment of Joints of Permanent Uni-Wall System and Floor Systems in Substructure
- Authors
- 천성철; 김승훈; 노삼영; 김갑수; 한범석
- Issue Date
- Apr-2012
- Publisher
- 한국건축시공학회
- Keywords
- CIP; uni-wall method; retaining wall; shear friction; wall-floor joint
- Citation
- 한국건축시공학회지, v.12, no.2, pp.230 - 242
- Indexed
- KCI
- Journal Title
- 한국건축시공학회지
- Volume
- 12
- Number
- 2
- Start Page
- 230
- End Page
- 242
- URI
- https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/35766
- DOI
- 10.5345/JKIBC.2012.12.2.230
- ISSN
- 1598-2033
- Abstract
- Recently the Permanent Uni-wall System (PUS) has been developed which improved the disadvantage of the Cast-In-Place Concrete Pile (CIP) and could be used as permanent retaining wall. In this study, joints between PUS and floor systems were developed. From analyses of the characteristics of design and construction of PUS, shear friction reinforcements with couplers were adopted for shear design of the joints. Twelve types of joints were developed which were classified according to the types of floor structures, wale, and piles of PUS. Two typical joints were tested and the joints showed satisfactory behaviors on the points of shear strength, stiffness, and serviceability.
Especially the shear strengths were much higher than the design strengths due to the shear keys which were by-products in splicing shear reinforcements. However, the shear strength of the joint is recommended to be designed by only shear friction reinforcement because shear key is not reliable and too brittle.