Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Breakdown Characteristics of Liquefied SF6 and CF4 Gases in Liquid Nitrogen for High Voltage Bushings in a Cryogenic Environment

Authors
Lee, S. H.Seong, J. K.Oh, S. H.Shin, W. J.Khan, Umer A.Lee, B. W.
Issue Date
Jun-2011
Publisher
Institute of Electrical and Electronics Engineers
Keywords
Breakdown; bushing; CF4; high voltage; HTS electrical equipment; liquefaction; LN2; partial discharge; SF6
Citation
IEEE Transactions on Applied Superconductivity, v.21, no.3, pp.1430 - 1433
Indexed
SCIE
SCOPUS
Journal Title
IEEE Transactions on Applied Superconductivity
Volume
21
Number
3
Start Page
1430
End Page
1433
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/37413
DOI
10.1109/TASC.2010.2090638
ISSN
1051-8223
Abstract
High voltage cryogenic insulation issues need to be addressed in order to promote the commercialization of high temperature superconducting (HTS) equipment. One of the critical components for superconducting devices is the bushing whose role is to safely supply high current to the device. Due to a steep temperature gradient, commercial bushings which have been insulated with SF6 gas could not be directly applied to cryogenic equipment due to liquefaction of SF6 in the cryogenic environment; therefore, alternative suitable structure and insulation methods should be developed. As a fundamental step in the development of the optimum bushings for HTS devices, the breakdown characteristics of liquid nitrogen mixed with liquefied insulating gases such as N-2, SF6 and CF4 have been investigated. In particular, we noted the insulation characteristics of CF4 gas whose liquefication temperature is much higher than SF6 gas. Thus, in order to investigate the possibility of substituting CF4 gas for SF6 gas for the bushings of HTS electrical equipment, impulse tests, AC withstanding voltage tests, and partial discharge (PD) tests have been performed. As a result of these tests, it was shown that mixtures of liquefied insulating gases have a much higher breakdown voltage compared to pure liquid nitrogen. Especially in a cryogenic environment, the usage of SF6 gas should be evaluated due to freezing effects. On the other hand, CF4 gas has shown excellent insulation properties even in a cryogenic environment and could be utilized as an insulation gas for high voltage bushings of HTS electrical equipment.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Bang Wook photo

Lee, Bang Wook
ERICA 공학대학 (SCHOOL OF ELECTRICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE