Selective detection of Salmonella typhimurium in the presence of high concentrations of masking bacteria

Authors
Lakshmanan, Ramji S.Guntupalli, RajeshHong, Jong WookKim, Dong-jooCheng, ZhongyangPetrenko, Valerly A.Barbaree, James M.Chin, Brayan Allen
Issue Date
Dec-2008
Publisher
Springer
Keywords
Bacteriophage; Biosensor; Magnetoelastic; Selectivity
Citation
Sensing and Instrumentation for Food Quality and Safety, v.2, no.4, pp.234 - 239
Indexed
SCOPUS
Journal Title
Sensing and Instrumentation for Food Quality and Safety
Volume
2
Number
4
Start Page
234
End Page
239
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/41889
DOI
10.1007/s11694-008-9049-x
Abstract
This article presents the results of an investigation into the ability of a magnetoelastic biosensor to detect Salmonella typhimurium, with high specificity, even in the presence of high concentrations of masking bacteria. Magnetoelastic biosensors are mass sensitive devices comprised of a magnetoelastic material that serves as the transducer and bacteriophage as the bio-recognition element. The sensors were tested individually with several different genus bacteria (Salmonella typhimurium, Salmonella entertidis, Escherichia coli O157:H7 and Listeria monocytogenes) to compare the bioprobe's affinity towards species other than the target analyte. The effect of the presence of one masking bacteria (E. coli) and two masking bacteria (E. coli and L. monocytogenes) in a mixture with S. typhimurium upon the response of the biosensor was studied. It was observed that the response of the sensors followed similar trends; however the sensitivity and the frequency changes were slightly lower for the mixtures. The sensitivity of the sensors exposed to only S. typhimurium was 161 Hz decade -1 and in mixtures with one and two masking bacteria were 131 Hz decade -1 and 127 Hz decade -1, respectively. Binding kinetics studies show that the dissociation constant (K d) and the binding valency (1/n H) samples with only S. typhimurium are 149 cfu mL -1 and 2.49, respectively. © Springer Science+Business Media, LLC 2008.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Jong Wook photo

Hong, Jong Wook
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE