Functionalized ultra-fine bimetallic PtRu alloy nanoparticle with high peroxidase-mimicking activity for rapid and sensitive colorimetric quantification of C-reactive protein

Authors
Gupta, Pramod K.Son, Seong EunSeong, Gi Hun
Issue Date
Mar-2021
Publisher
SPRINGER WIEN
Keywords
Bimetallic alloy; Nanozyme; Immunoassay; C-reactive protein; Colorimetric detection
Citation
MICROCHIMICA ACTA, v.188, no.4, pp 1 - 10
Pages
10
Indexed
SCIE
SCOPUS
Journal Title
MICROCHIMICA ACTA
Volume
188
Number
4
Start Page
1
End Page
10
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/429
DOI
10.1007/s00604-021-04775-4
ISSN
0026-3672
1436-5073
Abstract
The in situ synthesis is reported of citric acid-functionalized ultra-fine bimetallic PtRu alloy nanoparticles (CA@PtRu ANPs) through a simple one-pot wet chemical method. The cost-efficient CA@PtRu ANPs with an average diameter of 3.2 nm revealed to have enhanced surface area, peroxidase-like activity, high stability, and adequate availability of functional groups to bind biomolecules. Along with nanoparticle surface area, the surface charge has also significantly affected the peroxidase-like activity and the colloidal suspension stability. As an excellent immobilization matrix and peroxidase mimic, the CA@PtRu ANPs were utilized to develop non-enzymatic colorimetric immunoassay for rapid, selective, and sensitive quantification of C-reactive protein (CRP) biomarkers. In this immunoassay, CA@PtRu ANPs serve as enzyme mimic that significantly amplifies the color signals, and amine-functionalized silica-coated magnetic microbeads (APTES/SiO2@Fe3O4) act as CRP-recognizing capture probes. The absorbance curves of colorimetric immunoassay were measured in wavelengths between 550 and 750 nm, and the maximum absorbance at 652 nm was used to establish a linear relationship between absorbance and CRP concentrations. The developed colorimetric immunoassay showed rapid and sensitive quantification of CRP levels from 0.01 to 180 mu g mL(-1) with a LOD of 0.01 mu g mL(-1). Moreover, the mean recovery of CRP from spiked human serum samples lies between 97 and 109% (n = 3), which indicates that the proposed nanozyme-linked immunoassay has the potential to be used in rapid point-of-care applications.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF BIONANO ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seong, Gi Hun photo

Seong, Gi Hun
ERICA 공학대학 (DEPARTMENT OF BIONANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE