Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measurement of drug-target engagement in live cells by two-photon fluorescence anisotropy imaging

Authors
Vinegoni, ClaudioFumene Feruglio, PaoloBrand, ChristianLee, SungonNibbs, Antoinette E.Stapleton, ShawnShah, SunilGryczynski, IgnacyReiner, ThomasMazitschek, RalphWeissleder, Ralph
Issue Date
Jul-2017
Publisher
NATURE PUBLISHING GROUP
Keywords
PROTEIN ADP-RIBOSYLATION; IN-VIVO; SINGLE-CELL; PARP INHIBITION; POLY(ADP-RIBOSE) POLYMERASE; CYTOPLASMIC VISCOSITY; SCANNING MICROSCOPY; BREAST-CANCER; LIVING CELLS; POLARIZATION
Citation
NATURE PROTOCOLS, v.12, no.7, pp.1472 - 1497
Indexed
SCIE
SCOPUS
Journal Title
NATURE PROTOCOLS
Volume
12
Number
7
Start Page
1472
End Page
1497
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/9484
DOI
10.1038/nprot.2017.043
ISSN
1754-2189
Abstract
The ability to directly image and quantify drug-target engagement and drug distribution with subcellular resolution in live cells and whole organisms is a prerequisite to establishing accurate models of the kinetics and dynamics of drug action. Such methods would thus have far-reaching applications in drug development and molecular pharmacology. We recently presented one such technique based on fluorescence anisotropy, a spectroscopic method based on polarization light analysis and capable of measuring the binding interaction between molecules. Our technique allows the direct characterization of target engagement of fluorescently labeled drugs, using fluorophores with a fluorescence lifetime larger than the rotational correlation of the bound complex. Here we describe an optimized protocol for simultaneous dual-channel two-photon fluorescence anisotropy microscopy acquisition to perform drug-target measurements. We also provide the necessary software to implement stream processing to visualize images and to calculate quantitative parameters. The assembly and characterization part of the protocol can be implemented in 1 d. Sample preparation, characterization and imaging of drug binding can be completed in 2 d. Although currently adapted to an Olympus FV1000MPEPE microscope, the protocol can be extended to other commercial or custom-built microscopes.
Files in This Item
Go to Link
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > SCHOOL OF ELECTRICAL ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sung on photo

Lee, Sung on
ERICA 공학대학 (DEPARTMENT OF ROBOT ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE