A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

Authors
Kim, Han SooHa, Jang HoPark, Se-HwanKim, Jung BokKim, Yong KyunJin, Hyung-Ho
Issue Date
Jun-2009
Publisher
대한방사선방어학회
Keywords
ARMS (Area Radiation Monitoring System); Ionization Chamber; Long-term Stability; Linearity; Nuclear Power Plant
Citation
방사선방어학회지, v.34, no.2, pp 77 - 81
Pages
5
Indexed
KCICANDI
Journal Title
방사선방어학회지
Volume
34
Number
2
Start Page
77
End Page
81
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171722
ISSN
2508-1888
2466-2461
Abstract
An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 μR/h and 2.9 μR/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Kyun photo

Kim, Yong Kyun
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE