A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI
- Authors
- Kim, Han Soo; Ha, Jang Ho; Park, Se-Hwan; Kim, Jung Bok; Kim, Yong Kyun; Jin, Hyung-Ho
- Issue Date
- Jun-2009
- Publisher
- 대한방사선방어학회
- Keywords
- ARMS (Area Radiation Monitoring System); Ionization Chamber; Long-term Stability; Linearity; Nuclear Power Plant
- Citation
- 방사선방어학회지, v.34, no.2, pp 77 - 81
- Pages
- 5
- Indexed
- KCICANDI
- Journal Title
- 방사선방어학회지
- Volume
- 34
- Number
- 2
- Start Page
- 77
- End Page
- 81
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/171722
- ISSN
- 2508-1888
2466-2461
- Abstract
- An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 μR/h and 2.9 μR/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.