Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Separable and Recombinable Magnetic Robot for Robotic Endovascular Intervention

Authors
Sa, JunchiPark, JiminJung, EunsooKim, NahyunLee, DaeheeBae, SuhongLee, YongguJang, Gunhee
Issue Date
Apr-2023
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Catheters; Magnetic separation; Robots; Magnetic tunneling; Magnetic resonance imaging; Lesions; Permanent magnets; Surgical robotics; Steerable catheters; needles; medical robots and system; magnetic robot; endovascular intervention; external magnetic field
Citation
IEEE ROBOTICS AND AUTOMATION LETTERS, v.8, no.4, pp.1881 - 1888
Indexed
SCIE
SCOPUS
Journal Title
IEEE ROBOTICS AND AUTOMATION LETTERS
Volume
8
Number
4
Start Page
1881
End Page
1888
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/184926
DOI
10.1109/LRA.2023.3243801
ISSN
2377-3766
Abstract
This study presents a separable and recombinable magnetic robot (SRMR) to deliver and retrieve an untethered magnetic robot (UMR) to a target vascular lesion safely and effectively for robotic endovascular intervention. The SRMR comprises a delivery catheter and UMR connected to the end of the delivery catheter by a connecting section. An external magnetic field (EMF) interacts with the permanent magnet of the UMR; it can effectively generate magnetic torque and steer the delivery catheter to reach a target lesion. Furthermore, the rotating EMF allows the UMR of the SRMR to separate from the delivery catheter and perform the tunneling task. After completing the tunneling task, the UMR can be safely recombined with the delivery catheter in the vasculature via a simultaneous application of the EMF and suction force to the delivery catheter. The SRMR functions of steering, separation, movement, tunneling, drug delivery, and recombination are validated in a mimetic vascular model with a pseudo blood clot. Finally, the SRMR is successfully validated in an in vivo experiment of a mini pig's superficial femoral artery for contrast delivery, separation, movement, and recombination.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Gun Hee photo

Jang, Gun Hee
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE