Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Human elbow joint angle estimation using electromyogram signal processing

Authors
Yu, HeejungLee, An YongChoi, Youngjin
Issue Date
Dec-2011
Publisher
Institution of Engineering and Technology
Keywords
SYSTEM; FORCE; EMG SIGNALS; ARM; MUSCLES
Citation
IET Signal Processing, v.5, no.8, pp 767 - 775
Pages
9
Indexed
SCI
SCIE
Journal Title
IET Signal Processing
Volume
5
Number
8
Start Page
767
End Page
775
URI
https://scholarworks.bwise.kr/erica/handle/2021.sw.erica/36388
DOI
10.1049/iet-spr.2009.0203
ISSN
1751-9675
1751-9683
Abstract
This study proposes a real-time joint angle estimation method of human elbow by processing a biomedical signal of surface synergistic EMG (electromyogram) measured between biceps brachii and triceps brachii simultaneously. Actually, the EMG is known as a non-stationary signal, but the authors assume that it is quasi-stationary because a physical or physiological system has limitations in the rate at which it can change its characteristics. Based on the assumption, a preprocessing method to obtain pre-angle values from the raw synergistic EMG signal is firstly suggested, and then a method to estimate the joint angle through normalisation when there are external loads is discussed. In addition, an optimisation method to minimise the error between the normalised angle and real joint angle is proposed. Finally, the authors show the effectiveness of the suggested algorithm through experimental results.
Files in This Item
There are no files associated with this item.
Appears in
Collections
COLLEGE OF ENGINEERING SCIENCES > DEPARTMENT OF ROBOT ENGINEERING > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Youngjin photo

Choi, Youngjin
ERICA 공학대학 (DEPARTMENT OF ROBOT ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE